Certified Green Building Archives - Hammer & Hand Better building through service, craft, & science. Mon, 10 Mar 2025 22:28:33 +0000 en-US hourly 1 https://wordpress.org/?v=6.8.1 https://mld8ztyau83w.i.optimole.com/w:32/h:32/q:mauto/f:best/https://hammerandhand.com/wp-content/uploads/2021/11/HH_LOGO_S_RGB_7475_f.png Certified Green Building Archives - Hammer & Hand 32 32 New home in Sherwood on track to earn Earth Advantage Platinum certification https://hammerandhand.com/blog/new-home-sherwood-track-earn-earth-advantage-platinum-certification/ https://hammerandhand.com/blog/new-home-sherwood-track-earn-earth-advantage-platinum-certification/#respond Mon, 16 Jun 2014 20:06:17 +0000 http://hammerhanddev.wpengine.com/?p=4569 Rendering above by Scott | Edwards Architecture. “I didn’t really know about it,” said lead carpenter Patrick Conrad of the fact that the new green home he is building in Sherwood, designed by Scott | Edwards Architecture, is on track to earn Platinum certification as an Earth Advantage home.  (Visit our certified green homes to learn […]

The post New home in Sherwood on track to earn Earth Advantage Platinum certification appeared first on Hammer & Hand.

]]>
Rendering above by Scott | Edwards Architecture.

“I didn’t really know about it,” said lead carpenter Patrick Conrad of the fact that the new green home he is building in Sherwood, designed by Scott | Edwards Architecture, is on track to earn Platinum certification as an Earth Advantage home.  (Visit our certified green homes to learn about our approach, including project examples, videos, and articles.)

“We were just following our standard operating procedures,” Conrad said.  “It turns out that this way of building is consistent with Earth Advantage Platinum standards.”

Earth Advantage home certification emerged as a possibility when Sean Hendryx, energy analyst with Hammer & Hand, sat down with Earth Advantage’s Ryan Shanahan to explore possible energy efficiency incentives for the project.  Ryan took a look at the plans and Hammer & Hand’s specs and said that not only were incentives possible, but Earth Advantage certification was likely.

After a site inspection by Earth Advantage, it became clear that Platinum certification was within reach for the project.

While Earth Advantage home certification addresses energy performance, it also looks at a broad range of sustainability goals, including land use, materials, and water.  In this way it differs from Passive House, which brings a laser focus on energy use and comfort.

The home started with some things in its favor, in Earth Advantage’s eyes.  As a home in an existing neighborhood, it gets credit as an infill project and for its access to amenities.  Its sloping roof will direct rainwater to a concrete planter, earning credit for onsite infiltration.  And the home’s sealed combustion fireplace is key – if it were a conventional fireplace then certification would be precluded.

But to earn Earth Advantage certification, the house needs to achieve a suite of goals in planning and design, waste management, building envelope, heating and cooling, ventilation, lighting, appliances and water heating, interior materials, and water efficiency.

All signs show the project comfortably in Platinum territory.  Verification will come after project completion.  Fingers crossed!

Siding is currently underway at the site – see the photos from Patrick:

Siding underway at Sherwood new home building project

Siding underway at Sherwood new home building project

The post New home in Sherwood on track to earn Earth Advantage Platinum certification appeared first on Hammer & Hand.

]]>
https://hammerandhand.com/blog/new-home-sherwood-track-earn-earth-advantage-platinum-certification/feed/ 0
Legacy Building: Reaching Net Zero, Part III https://hammerandhand.com/blog/legacy-building-reaching-net-zero-part-iii/ https://hammerandhand.com/blog/legacy-building-reaching-net-zero-part-iii/#respond Tue, 28 Oct 2014 21:51:14 +0000 http://hammerhanddev.wpengine.com/?p=5783 This post is the third of three examining net zero energy building. The first two posts, “Is Solar Smart?” and “Performance Matters,” explored the energy generation and energy conservation sides of the net zero equation. This post takes a step back and evaluates how well this approach to building delivers health and happiness. To geek […]

The post Legacy Building: Reaching Net Zero, Part III appeared first on Hammer & Hand.

]]>
This post is the third of three examining net zero energy building. The first two posts, “Is Solar Smart?” and “Performance Matters,” explored the energy generation and energy conservation sides of the net zero equation. This post takes a step back and evaluates how well this approach to building delivers health and happiness.

To geek out is an occupational hazard for the high performance builder. There’s so much cool stuff to chew on, from the building science behind the latest wall assembly detail to the intricacies of the western electrical grid and everything in between. The power that we have to revolutionize building efficiency and reach beyond net zero energy building is exciting.

(Visit our Zero Energy Homes page for more about H&H’s approach, including project examples, videos and articles.)

But one question is more important than all of the technical stuff surrounding net zero energy building: do these buildings increase the health and happiness of occupants?

Because ultimately we want to be in the business of building legacy buildings: buildings that are so high performing that they’re part of the climate solution, that are so durable that they’ll last for generations, and that are so gracious to inhabit that people will care about them for generations. All three of these qualities must be in place for a building to truly be sustainable and leave a lasting legacy.

So, are net zero energy buildings “gracious?”

It depends.

Not if they achieve net zero status by focusing only on onsite generation of energy and ignore building performance. A code-built building that happens to be powered by a bunch of solar panels onsite will be no more comfortable or healthy to inhabit than your run-of-the-mill tract home.

But that case is rare. As the previous “Performance Matters” post explained, most net zero energy projects are up against space limitations that dictate modestly sized solar arrays. So most net zero energy projects have to employ high performance building strategies like Passive House to meet their energy targets.

And that does mean that they are gracious. The US Department of Energy says so…

The chart below was presented last month by Sam Rashkin, Chief Architect at the Building Technologies Offices of the DOE. It compares four different building types across a series of metrics, many focused on health and happiness. The light green bar represents homes built to the DOE Zero Energy Ready Home certification, a green building standard that closely parallels Passive House. The dark green bar shows PHIUS+ certified Passive House projects. The blue bar is for ENERGY STAR® homes. And the gray is for existing homes built between 1990 and 2010.

DOE Zero Energy Ready Home and PHIUS+ chart

On all measures, the DOE Zero Energy Ready Homes and PHIUS+ Passive Houses blow the competition out of the water. According to the Department of Energy, this high performance approach to building not only achieves revolutionary energy performance, it also delivers health, comfort, and quality that is far superior to other construction standards, even its own ENERGY STAR certification.

Why? Because Zero Energy Ready Home and Passive House projects combine advanced building science knowledge with field-verified precision: flawless execution of the best high performance designs.

When you’re inside one of these buildings you experience a haven of thermal comfort, solidity, and quiet created by the structure’s airtight, super-insulated construction. But you also enjoy an unparalleled sense of inside-outside connection thanks to a continuous supply of filtered fresh air, natural daylighting, and views to the outside through high performing windows. In human ecology-speak it’s the “protected prospect,” cozy but connected.

Gracious to inhabit, durable, and part of the climate solution – when we harness high performance building to achieve net zero energy we create legacy buildings.

Save

Save

The post Legacy Building: Reaching Net Zero, Part III appeared first on Hammer & Hand.

]]>
https://hammerandhand.com/blog/legacy-building-reaching-net-zero-part-iii/feed/ 0
Construction Methods and Approach to the Glasswood Commercial Passive House Retrofit https://hammerandhand.com/blog/construction-methods-approach-glasswood-commercial-passive-house-retrofit/ https://hammerandhand.com/blog/construction-methods-approach-glasswood-commercial-passive-house-retrofit/#comments Thu, 04 Dec 2014 23:41:19 +0000 http://hammerhanddev.wpengine.com/?p=5992 This article was originally published in the Journal of Green Building, Volume 9, Number 3, Pages 23-36. INTRODUCTION As the first commercial Passive House retrofit in the United States, the Glasswood project demonstrates the potential for high performance, low-load buildings to transform the energy efficiency, occupant experience, and marketability of existing commercial spaces, all at […]

The post Construction Methods and Approach to the Glasswood Commercial Passive House Retrofit appeared first on Hammer & Hand.

]]>
This article was originally published in the Journal of Green Building, Volume 9, Number 3, Pages 23-36.

INTRODUCTION
As the first commercial Passive House retrofit in the United States, the Glasswood project demonstrates the potential for high performance, low-load buildings to transform the energy efficiency, occupant experience, and marketability of existing commercial spaces, all at an affordable cost. The owners of this historic building set out to create a restaurant on the ground floor and office space on the second floor that would offer super-efficient energy performance and superior comfort while preserving the structure’s historic character. Embedded in a walkable, transit-rich neighborhood, the project revolutionized the performance of the building while contributing to the vitality of its urban surroundings. Passive House design and construction was by Hammer & Hand, with architectural design by Scott | Edwards Architecture.

Glasswood Commercial Passive House Retrofit - BEFORE
FIGURE 1. The 1916 building before the retrofit.

Context
When the owners purchased the Glasswood building it was a derelict commercial structure (Fig. 1) surrounded by an ongoing urban renaissance of development along Southeast Division Street in Portland, Oregon. Built in 1916, the building had former lives as a barbershop, upholstery shop, guitar repair shop, and apartments. But due to deferred maintenance, the structure had fallen into such a state of disrepair that a major renovation was necessary to save the building from the wrecker’s ball. The owners were committed to adaptive reuse of the structure—repurposing it with a restaurant on the ground floor and office above (Fig. 2).

Glasswood Commercial Passive House Retrofit now
FIGURE 2. The completed retrofit, with restaurant below and Passive House office/event space above.

This occupancy change triggered a full modernization. From the beginning of project development it was clear that the building’s envelope would need to be completely reskinned to allow for required structural upgrades, to make the envelope improvements necessary to meet modern energy code, and to meet the elevated aesthetic norms of a revitalized streetscape. The owners recognized that this reworking of the envelope opened up the opportunity for a cost-effective, high-performance, deep-energy retrofit of the building. In fact, with just a slight increase in the thickness of the new exterior insulation already required by code, a bit of extra attention paid to airtightness, and other modest performance tweaks, the upstairs floor of the project could meet the performance requirements of Passive House, the world’s most stringent building energy standard.

About Passive House
The Passive House approach to construction harnesses advanced building science to achieve transformative gains in building energy performance, reducing buildings’ heating and cooling loads by 80% at nominal extra construction cost. (Visit our Passive House page to learn about H&H’s work in this realm, including project examples, videos, and articles.) The standard’s laser-like focus on energy performance is measured through three metrics:

  • Airtightness equal to or better than 0.6 air changes per hour at 50 pascals of pressure, as measured by a blower door fan test.
  • Annual heating (and cooling) demand of less than or equal to 4.75 kBtu/sf/yr.
  • Primary energy demand of less than or equal to 38.1 kBtu/sf/yr.

If a project meets these three metrics then it can be Passive House certified. Passive House Institute US is the US-based certifier, and offers a third-party verified, quality assured Passive House certification called PHIUS+, which Glasswood earned for its upstairs office space. (NOTE: PHIUS is now working on climate-specific North American Passive House standards.)

Given that significant retrofit interventions were necessary at Glasswood from the beginning of the project, the additional cost to transform the structure into a high performance building was small. At just $6/sf extra, our Passive House retrofit of the 1400sf upstairs space consumes 80% less energy for heating and cooling than a code-built commercial space. Still, retrofitting a 100-year-old mixed-use structure to super-efficiency took significant design work and high performance detailing.

This paper will: (1) identify the Passive House design challenges that the Glasswood project presented; (2) summarize the solutions to those challenges; (3) detail the construction methods employed to complete the project successfully; and (4) detail lessons learned.

I. DESIGN CHALLENGES SUMMARY
How do we, in the 21st century, approach the renovation of historic but inefficient buildings? The fuel burned to operate them speeds global climate change, but bulldozing and rebuilding on any significant scale is not an option—too much architectural heritage and embodied energy wasted. The Glasswood project presented these three primary design challenges: (a) how to retrofit to the Passive House standard on a building with an inherently energy-intensive commercial kitchen; (b) how to transform the performance of the structures while preserving its architecture; and (c) how to design a HVAC strategy that delivers comfort and fresh air in the micro-load context of a Passive House space with highly variable occupancy rates.

a. Separation from the Restaurant
Given the challenge of incorporating a commercial kitchen into a Passive House structure, the critical site solution at the Glasswood retrofit is the adiabatic layer (Fig. 3) that separates the Passive House office space on the upper floor from the high performance (but not Passive House) restaurant (Xico) below. (Due to the intensive energy use and air change requirements of commercial kitchens, restaurants are usually not suitable for Passive House certification.) By treating the horizontal space between the office and restaurant as a partition wall, Hammer & Hand isolated the office as its own self-contained unit. While partially thermally connected with the restaurant below, everything else about the building systems in the office is 100% separated from the ground floor, including air sealing, ventilation, heating and cooling, and domestic hot water. The adiabatic layer made Passive House possible for this structure.

Adiabatic layer at Glasswood Commercial Passive House Retrofit
FIGURE 3. An adiabatic layer isolates the Passive House upstairs from the restaurant downstairs.

b. Reusing Existing Shell
In constructing the project’s high performance envelope Hammer & Hand maintained the shell’s existing 2×4 wood framing and added layers inside and out. As part of the project’s seismic retrofit, the team installed new structural exterior sheathing and taped all seams with vapor-permeable tape to create a wind-tightness layer. The R-33 assembly augments the existing 2×4 wall cavity with an inboard 2×4 service cavity, with both cavities filled with high-density cellulose. The assembly is wrapped with 2” EPS foam, exterior gypsum, WRB, and rain screen. The roof insulation is R-45 water-blown low density spray polyurethane (LDSPF) against the underside of the roof system with a sealed interior OSB air tightness layer.

The project employs high performance windows with insulated fiberglass frames and high solar heat gain, triple-pane glazing. Through a process detailed later in this article, Hammer & Hand installed each window using liquid applied flashings. To create seamless air and water tightness, this liquid applied barrier goes into all penetrations and rough openings in the building envelope.

c. Mechanical Simplicity
The mechanical system strategy at Glasswood (Fig. 4) became one of the simplest elements of the project, thanks to the micro-loads of Passive House. The space is ventilated using an 88% efficient Zehnder 550 ComfoAir HRV, controlled by a carbon dioxide sensor that modulates the ventilation rate depending on occupancy. The unit maximizes the cooling potential through night flush ventilation. In this mode the HRV bypasses the heat recovery core and exchanges all the air in the building a number of times with outside air, effectively lowering the temperature inside the building to that of the exterior in cooling demand situations.

Mechanical Plan for Glasswood Commercial Passive House Retrofit
FIGURE 4. Design simplicity of the mechanical system at Glasswood.

A heat pump hot water heater, programmed to run afterhours, provides domestic hot water for the lavatory and kitchenette. During summer months this unit partially offsets the space’s cooling load by pulling heat from the interior air. During winter months the unit switches over to electric resistance heat to avoid cooling the space. Heating and cooling are provided by one Mitsubishi ductless minisplit.

The design at Glasswood incorporates open space, natural light, and high-quality, efficient artificial lighting. The daylighting scheme for the space includes three daylighting zones equipped with sensors that monitor daylight and occupancy so that artificial lighting adjusts automatically to the natural light provided by the space’s large high-performance windows. Initial modeling of conventional lighting systems showed the lighting satisfying the entire heating load during winter and leading to excessive cooling load in summer, so daylighting and use of efficient fixtures were key to the Passive House strategy.

The Result
The project surpassed all three metrics of Passive House certification, with an airtightness measurement of just 0.30 ACH50 (compared to the 0.60 ACH50 required by Passive House), annual heat demand of 4.14 kBtu/sf/yr (compared to the 4.75 kBtu/sf/yr required), and primary energy of 36.9 kBtu/sf/yr (compared to the 38.1 kBtu/sf/yr required).

But Passive House projects not only revolutionize energy efficiency, they also revolutionize the experience of being inside. Glasswood is an airy, quiet, comfortable, fresh-air-infused space (Fig. 5). Although the structure overlooks busy Division Street, the project’s high-performance windows and advanced building envelope shield the interior space from noise outside. And the freshness of interior air is palpable, exposing how accustomed we have become to conventional interior spaces that are stale and oxygen-starved. Energy consumption for heating and cooling is reduced by 80% compared to a conventional commercial space. The addition of a modest solar array could easily bring the project to net positive energy.

Interior of Glasswood Commercial Passive House Retrofit
FIGURE 5. Interior of the Passive House office/event space.

III. CONSTRUCTION DETAILS
Our examination of the construction of Glasswood, below, is organized into five categories: a. adiabatic layer; b. wall assembly; c. window installation; d. roof assembly; and e. mechanical systems.

a. Adiabatic Layer
The adiabatic layer at Glasswood separates the office and event space upstairs from the restaurant below, a key move in allowing the upstairs space to achieve Passive House certification

given the energy-intensive nature of the commercial kitchen downstairs. Adiabatic layers are employed in energy modeling as a way of recognizing those conditions where the modeled space abuts another thermally conditioned space—circumstances in which we need to air seal between units but do not need to provide the kind of thermal resistance that would be required if the partition were managing exterior air or ground source temperature differentials.
The airtightness of Glasswood’s adiabatic layer is provided by a layer of OSB with taped seams and penetrations. (This approach is also used in Glasswood’s wall assembly, detailed below.) Partially to mitigate for sound and partially to provide thermal resistance, the adiabatic layer is insulated enough to buffer temperature deltas caused by the different occupancies of the two spaces.

b. Wall Assembly
Just as the adiabatic layer made Passive House practical for the project, so too did the approach to its wall assembly (Fig. 6). Because the project involved a change of uses, a significant seismic and thermal upgrade to the structure was already required by code, including the addition of a monolithic layer of exterior insulation. So even before any Passive House considerations were made, the team knew it would be opening up existing walls and recladding the building’s exterior. From both a cost and construction perspective, the conditions were ideal for a Passive House retrofit; fairly simple and inexpensive additions to the wall could bring it up to Passive House levels of performance. The constituent components of this performance are strict, measured airtightness and modeled, highly thermally resistant construction. By preserving the existing exterior wall, the team would be well down the road to preserving the structure’s architectural character and integrity as well.

Glasswood Passive House Wall Assembly
FIGURE 6. High performance wall assembly at Glasswood builds on existing stud wall.

To shore up the shear strength of the structure, Hammer & Hand added a layer of plywood sheathing to the exterior face of the existing 2×4 stud wall. Working outwards from this sheathing, the team layered on continuous EPS insulation followed by a layer each of Densglass, 30-minute paper, rainscreen, and new cladding. Working inwards from the exterior sheathing, Hammer & Hand filled the existing wall cavity with cellulose insulation and then added a new layer of OSB with taped seams and penetrations to create the air barrier (Fig. 7). After confirming appropriate airtightness with a blower door fan test, the team installed a framed service cavity layer, insulated it with cellulose, and finished with a layer of interior gypsum.

OSB with Siga tape at Glasswood Passive House retrofit
FIGURE 7. Air barrier created by OSB panels taped with vapor permeable Siga tape.

By sandwiching the taped OSB air barrier between the original 2×4 wall and the new 2×4 service cavity, this vital layer of the assembly is protected from puncture or other damage that commonly occurs when the airtightness layer is close to the interior or exterior. The air barrier also offers a consistent level of vapor permeability, as the permeability of the Siga tape used on panel seams equals that of the OSB panels themselves.

For moisture management, the exterior Hardie siding handles bulk water with a 3/4” ventilated rainscreen cavity whose rapid rate of air changes facilitates drying of the assembly. Following Building Science Corporation recommendations, we used Douglas fir furring strips in lieu of pressure treated lumber in order to minimize environmental impact and lower construction material cost. The water-resistive barrier (WRB) is a combination of the Prosoco R-Guard system at punched openings, integrated into a VaporShield membrane installed over the Densglass. This wall will dry primarily to the interior, though it is open to the exterior through the thinner layer of EPS and ventilated rain screen cavity. Interior moistureconditions are monitored through the ventilation system to ensure that vapor is not driven into the assembly from interior spaces.

The exterior cladding is supported by the furring strips as mentioned above. The furring strips are held in place through FastenMaster HeadLOK foam fasteners that act as struts anchored into the structural framing of the original building. These fasteners are specifically developed to stay rigid through a loose layer, such as insulation. This type of fastening of cladding systems through exterior insulation is becoming more common as commercial code increasingly adopts monolithic exterior insulation as part of more stringent energy performance requirements. The 2” of EPS exterior insulation coupled with 7” of dense packed cellulose insulation in the two wall cavities, plus the framing factor, brings the wall assembly to an insulative value of R-33. The wall assembly’s super-insulation and airtightness are both critical to the project’s success at meeting the airtightness and energy demand metrics of Passive House certification.

c. Window Installation
Windows, and their installation, are critical to any Passive House project, as each window opening represents a hole in an otherwise fairly impervious envelope. Each penetration introduces the potential for thermal loss and air and water intrusion. High performance components are key. At Glasswood we used Cascadia 300 series triple pane windows with insulated fiberglass frames and high solar heat gain; an excellent window that gives R-5 in assembly. Like the walls that surround them, these thermally resistant windows, installed in airtight assemblies, were central to the project’s strategy to reach Passive House levels of performance.

Any window is, by nature, failure-prone. They are complex, full of junctions, corners, and seams—rife with opportunity to leak moisture. Although high-quality windows may take decades to fail, it is not a matter of if windows leak, but when. And given that super-insulated, airtight wall assemblies do not dry as readily as the leaky walls of conventional construction, Hammer & Hand realized early on that we had to detail our rough openings to be: (1) completely water-resistant to keep water from penetrating the wall assembly; (2) vapor-permeable to let construction moisture, seasonal moisture fluctuation and exterior moisture evaporate from the wall; and (3) airtight. Airtightness is crucial in high performance construction partly because airtight detailing also helps ensure proper detailing for energy performance and prevention of water intrusion. If you are controlling for air, you are controlling for energy and moisture.

In the Pacific Northwest, the simplest way Hammer & Hand has found to achieve this is through vapor-permeable liquid-applied flashing. Any rain that hits the window opening or leaks through the window drips down to a liquid-applied membrane installed around it into the rough opening (with the window air-sealed to the inside) and out to the exterior moisture-management layer. On the Glasswood project—and most other Hammer & Hand projects—we used a liquid applied flashing system manufactured by Prosoco called Fast Flash.

As an installation method, liquid-applied flashing is as close to foolproof as anything we know. It is much harder for a carpenter having a bad day to make mistakes with a liquid-applied membrane than with the “origami” of tapes, peel and stick, and papers. Window installation sequences using the conventional methodology involve anywhere between 50 and 100 separate steps per opening. The chances of getting every install done perfectly approach zero as you multiply across the number of openings in a typical building. Liquid applied flashing presents not only fewer steps, but also more verifiable results. Errors like inadequate coverage are easy to identify because they are not hidden by layers of tapes and paper. A little spot touching fixes the problem.

Window installation at Glasswood involved four steps:

1. Prepare the rough opening. The first step was to ensure that the rough openings were ready for the install. In this retrofit context Hammer & Hand placed a secondary sloped sill to span the framed sill, exterior EPS, and cladding layers. (Fig. 8) This served both to facilitate drainage outward and to provide a fresh, uniform surface for prep of the rough opening.

Secondary sill going in at Glasswood
FIGURE 8. Secondary sill being placed to span the framed sill, exterior EPS, and cladding layers.

2. Reinforce structural seams and embed transition membrane. We used a vapor-permeable fluid-applied joint and fastener treatment (Joint & Seam) to coat fastener penetrations and seams between framing, sheathing, the secondary sill, EPS, and Densglas. To tie the rough opening to the building’s exterior moisture management system, Hammer & Hand then embedded sheets of Sure-Flash into the wet Joint & Seam, creating a WRB transition flap under which the exterior sheet WRB can shingle in. (Fig. 9)

Transition membrane going in at Glasswood
FIGURE 9. Transition membrane embedded in Joint & Seam treatment.

3. Apply liquid flashing. Next Hammer & Hand applied the liquid flashing to the rough opening, careful to create a consistent layer of the product throughout the rough opening. (Fig. 10) The team extended this layer of flashing out onto the face of the building at least 9 inches in all four directions, tying into the building’s water-resistive barrier (WRB) system. (Fig. 11)

Rough opening completely flashed at Glasswood Passive House retrofit
FIGURE 10. Liquid applied flashing applied to rough opening.

There are two reasons for this approach. First, liquid-applied flashing self-gaskets, protecting the integrity of the exterior sheathing immediately around the rough openings, an area that receives lots of fasteners and penetrations. Second, if water does get driven between the exterior sheet goods layer and the liquid-applied flashing, gravity can take over and pull that water down the assembly, where it can be managed by the Sure-Flash transition membrane. Nine inches, based on test chamber results, provides enough horizontal room for wind-driven moisture to be drawn down by gravity, ensuring that water laps out over the WRB system and drains off the building.

WetFlash to SureFlash transition at Glasswood
FIGURE 11. Liquid applied flashing extended pas the SureFlash membrane at least nine inches out from rough opening.

4. Install the window. Hammer & Hand placed the windows dead level on setting blocks, with a consistent 3/8” gap between window and opening. The team then installed a closed-cell foam backer rod around the perimeter of that gap and applied a high-quality sealant compatible with the flashing (Air Dam) (Fig. 12).

Interior seal for high performance windows at Glasswood
FIGURE 12. Air Dam sealant being applied.

This approach created an airtight, waterproof interior sealant joint, connecting the interior edge of the window with the liquid flashing in the rough opening. Any water that leaks through the window will hit outside that seal and drain to the exterior. Not only does bringing the seal so far to the interior create a last line of defense on the inner plane of the window, but it also is less exposed to temperature extremes and UV light. That seal will outlive the window. (NOTE: For more about our approach to window installation, see our Best Practices Manual.)

d. Roof Assembly
From interior to exterior, the R-45 roof assembly consists of: gypsum suspended on 2×4 furring that functions as a service cavity for lights and wires; the OSB airtightness layer; the existing modified ladder truss framing with low density spray foam insulation sprayed to the bottom side of the original roof sheathing. Continuing outwards is the roof underlayment and a TPO membrane. This is a very low-sloped commercial roof with no venting to the underside of the sheathing. The system relies on the airtight characteristics of the OSB and low-density spray foam to sufficiently prevent and retard vapor transmission and potential condensation at the sheathing. As an integral component of the project’s thermal envelope and air barrier, the roof’s super-insulation and airtightness is essential to Glasswood’s Passive House performance.

e. Mechanical Systems
A Zehnder 550 ComfoAir HRV provides a continuous supply of preconditioned fresh air to the space. Systems like this one are vital to airtight Passive House structures because they deliver superior indoor air quality while also preserving thermal energy inside the envelope. This system’s ventilation rate is controlled by carbon dioxide sensors that modulate fresh airflow based on CO2 levels detected, with manual boosting at the kitchen and bath. When exterior temperatures conditions are right—like on summer nights—the unit automatically bypasses the HRV core and provides direct fresh air to the space.

At Glasswood, the HRV serves three main functions conventionally kept separate: (1) fresh air ventilation; (2) exhaust; and (3) heat and cooling distribution. The unit is set to run at its minimum setting at all times. This provides the space with 0.3 air changes per hour, or approximately one entire volume of air change every three hours. This filtered air is distributed into the open space of the building. The unit’s exhaust intakes are located in the bathroom and kitchen, drawing air from those areas continually with boosts as needed to handle odors and moisture. Given the rate of air changes per hour, the HRV effectively mixes and therefore redistributes the air in the entire space at a rate that provides even thermal distribution on all but the highest demand days.

To meet the project’s micro heating and cooling loads, Glasswood employs a simple ductless minisplit Mitsubishi MSZ-FE18NA, 18,000 Btu/h heat pump. It has three components: (1) an exterior compressor and (2) an interior heating and cooling “head” connected by a (3) line set that carries compressed gas and electrical between the two units. This minisplit heats and, primarily in the case of Glasswood, cools interior air via the head location.

A heat pump hot water heater, slightly thermal positive to interior air temperatures in the winter, provides significant cooling in the summer when it switches to heat pump-only mode, providing about one ton of cooling.

To help Glasswood meet the Passive House standard’s primary energy demand metric, the project employs daylighting, occupancy and photo sensors, and efficient LED lighting to decrease electric consumption for lighting by more than 50% compared to code.

IV. CONCLUSION – LESSONS LEARNED
In adaptive reuse projects that involve the removal of interior finishes and re-skinning the building, there is a golden opportunity to leverage existing codes and, with a small additional cost, increase a building’s shell performance to the point where heat and cooling load are driven toward zero. In the context of commercial Passive House building, cooling load becomes the driving factor even more quickly than is the case in conventional commercial construction, as the heat load is almost always satisfied by operation and occupant inputs.

The payback for these additional costs is anywhere between 3 and 7 years, including the expense of alternative energy systems. By emphasizing energy conservation first through a high performance shell and mechanical system, Glasswood is also well on its way to net positive energy. On-site energy generation via a modest solar PV array is all that is needed to get there.

We realized that in this low load project, the difference between the space’s regular occupancy of 8 people and occasional occupancy of 70 people yielded even more radical results than would be found in a conventional building. Fortunately we installed a much larger HRV than was necessary for the lower occupancy rates, which helps to provide necessary fresh air for large groups. Even with this consideration, in high-use situations the occupants often open the windows to provide additional fresh air and ventilation. But that is fine; open windows are a perfectly acceptable passive cooling and ventilation strategy in Passive House buildings.

Because the occupants of Glasswood have become acclimated to the very small interior temperature differentials of Passive House buildings (plus or minus 2 degrees Fahrenheit from the warmest to coldest spot in the space,) they have become more sensitive than most to larger differentials. So they noticed the slight, 5 to 7 degree Fahrenheit overheating caused by solar gain through the south-facing windows during spring and fall. Hammer & Hand fixed the issue cheaply and effectively with seasonal application of insect screens on the south facing windows, a low-tech way to reduce insolation into the space. But this temperature differential would not normally even be addressed in a conventional structure. It became a nuisance for the occupants at Glasswood because they had become accustomed to even thermal comfort. The same is true of exterior noise. An open window is much more apparent to occupants that are accustomed to working in a relatively silent environment. Street noise is perceived as much louder in this Passive House space with a window open than in an already-noisy conventional structure.

The post Construction Methods and Approach to the Glasswood Commercial Passive House Retrofit appeared first on Hammer & Hand.

]]>
https://hammerandhand.com/blog/construction-methods-approach-glasswood-commercial-passive-house-retrofit/feed/ 1
US Department of Energy awards highest level of certification to two H&H homes https://hammerandhand.com/blog/us-department-energy-awards-highest-level-certification-two-hh-homes/ https://hammerandhand.com/blog/us-department-energy-awards-highest-level-certification-two-hh-homes/#respond Tue, 16 Dec 2014 17:00:24 +0000 http://hammerhanddev.wpengine.com/?p=6073 The US Department of Energy just granted its highest level of green home certification, “Zero Energy Ready Home,” to Karuna House and Pumpkin Ridge Passive House, both built by Hammer & Hand. “A DOE Zero Energy Ready Home is a high performance home which is so energy efficient that a renewable energy system can offset […]

The post US Department of Energy awards highest level of certification to two H&H homes appeared first on Hammer & Hand.

]]>
The US Department of Energy just granted its highest level of green home certification, “Zero Energy Ready Home,” to Karuna House and Pumpkin Ridge Passive House, both built by Hammer & Hand.

“A DOE Zero Energy Ready Home is a high performance home which is so energy efficient that a renewable energy system can offset all or most of its annual energy consumption.

Only a select group of the top builders in the country meet the extraordinary levels of excellence and quality specified by the US Department of Energy guidelines.”

– US Department of Energy

To be clear, Karuna and Pumpkin Ridge aren’t just “ready.” They have already achieved  “zero energy” or better thanks to their 10kW solar PV arrays. But we like the DOE’s decision to focus on the energy efficient, zero energy “readiness” of homes with this top certification. It rightly prioritizes the conservation side of the “conservation + generation = zero energy” equation. You can’t achieve the certification by slapping tons of PV panels on a conventional house; the house itself has to perform to high standards.

This focus dovetails perfectly with the Passive House approach to construction and its emphasis on low energy loads. DOE recognizes this, and views Passive House (PHIUS+) as a close parallel to its Zero Energy Ready Homes certification. (NOTE: visit our Passive House and Zero Energy Homes pages for more about our approach, including project examples and video.) In the chart below, the two green, high performing bars depict how DOE measures the superiority of Passive House and Zero Energy Ready Homes compared to Energy Star and conventional homes (gray and black, respectively).

Zero Energy Ready Home graph

The chart also makes the case that Zero Energy Ready Homes (and Passive Houses) achieve much more than great energy efficiency. They make occupants healthy and happy. (For more about health, happiness, and legacy building, see the post, “Legacy Building: Reaching Net Zero, Part III.”)

P.S. DOE’s certification of Karuna and Pumpkin Ridge comes on the heels of national recognition for the two projects: both won 2014 Green Home of the Year awards from Green Builder magazine.

Save

The post US Department of Energy awards highest level of certification to two H&H homes appeared first on Hammer & Hand.

]]>
https://hammerandhand.com/blog/us-department-energy-awards-highest-level-certification-two-hh-homes/feed/ 0
Solar Energy and the Black Swan https://hammerandhand.com/blog/solar-energy-and-the-black-swan/ https://hammerandhand.com/blog/solar-energy-and-the-black-swan/#comments Mon, 06 Jul 2015 17:00:07 +0000 http://hammerhanddev.wpengine.com/?p=6940 In his book, “The Black Swan: the Impact of the Highly Improbable,” Nassim Nicholas Taleb describes how the world has been shaped by a series of massive shifts in established systems: change events that virtually no one saw coming. “The way things have always been” suddenly gets turned on its head. Taleb makes the case that our […]

The post Solar Energy and the Black Swan appeared first on Hammer & Hand.

]]>
In his book, “The Black Swan: the Impact of the Highly Improbable,” Nassim Nicholas Taleb describes how the world has been shaped by a series of massive shifts in established systems: change events that virtually no one saw coming. “The way things have always been” suddenly gets turned on its head. Taleb makes the case that our assumption that established systems will persist indefinitely makes us blind to the possibility of potentially earth-shattering changes, like the fall of the Berlin Wall or the attacks of 9/11.

Taleb uses the life of the turkey to illustrate the point:

Life of a turkey as lesson for energy markets and disruption of solar power

Graphs like this are sometimes cited to warn of things like ecosystem collapse. And when we think of the Black Swan and the climate crisis we can be forgiven for dwelling on the negative. But Black Swan events also describe positive change.

Take a look at this jaw-dropping graph from a report by the investment bank Sanford Bernstein, for example:

Sanford Bernstein: Solar energy prices dropping

The wavering lines across the bottom of the graph show the price of fossil fuel-generated energy. The dive-bombing line at the right shows the price of solar energy falling from the sky out of nowhere, very much like a Black Swan. Solar energy is suddenly giving dirty energy a run for its money.

This graph below by Brian McConnell shows the same thing, but with a logarithmic y-axis that visually flattens the game-changing drop in solar price.

Dropping solar prices to disrupt fossil fuels

It looks like solar energy will disrupt energy markets and conventional dirty energy production very soon.

You know how computer chip innovation is described by “Moore’s Law,” that says that the size of chip transistors halves every 18 months? Here’s what that does to the price of computing power:

Moore's Law and price of transistors

Like computer chips (and unlike oil) solar energy is a technology. So innovation can be a big deal. It turns out that solar panel price follows something akin to Moore’s Law, called “Swanson’s Law,” that says that solar panel price decreases by 20% for every doubling of global manufacturing capacity. Here’s what that’s doing to the price of solar energy:

Swanson's Law and solar pv price

We’re seeing similar decreases in wind power and battery cost, too. (Have you noticed what Elon Musk is up to lately?)

Now I know I’m mixing world views here: one (the Black Swan) saying we’re unwise to predict the future based on the past, and the other (Swanson’s Law) saying that we’re safe to assume that future drops in solar energy costs will continue along past trajectories.

But here’s my point: we’re in game-changing, system-disrupting, exponential growth territory with renewable energy right now. As we contemplate the 59% reduction in global CO2 emissions that the International Energy Agency says is necessary by 2050 to limit warming to 2 degrees C, this provides some hope.

For more musings about renewables, climate change, and how they relate to high performance buildings, check out these posts:

Is Solar Smart? Reaching Net Zero, Part I

On the Jevons Paradox, Climate, and Fighting Defeatism

(Black Swan photo by Russell Street, some rights reserved under a creative commons license.)

Save

The post Solar Energy and the Black Swan appeared first on Hammer & Hand.

]]>
https://hammerandhand.com/blog/solar-energy-and-the-black-swan/feed/ 1
H&H Wins U.S. Department of Energy’s 2015 Housing Innovation Award https://hammerandhand.com/blog/hh-wins-u-s-department-of-energys-2015-housing-innovation-award/ https://hammerandhand.com/blog/hh-wins-u-s-department-of-energys-2015-housing-innovation-award/#respond Thu, 13 Aug 2015 21:53:05 +0000 http://hammerhanddev.wpengine.com/?p=7127 In a statement this morning the U.S. Department of Energy announced that it had awarded Hammer & Hand with its prestigious 2015 Housing Innovation Award. “The U.S. Department of Energy (DOE) knows there is one chance during home construction to lock in critical performance measures that can take the homeowner experience to a new level […]

The post H&H Wins U.S. Department of Energy’s 2015 Housing Innovation Award appeared first on Hammer & Hand.

]]>
HIA Zero Home Winner Logo In a statement this morning the U.S. Department of Energy announced that it had awarded Hammer & Hand with its prestigious 2015 Housing Innovation Award.

“The U.S. Department of Energy (DOE) knows there is one chance during home construction to lock in critical performance measures that can take the homeowner experience to a new level of efficiency, comfort, health, and durability,” wrote the DOE in its statement. “But it will take housing industry leadership to provide this opportunity to American homebuyers. That’s why DOE proudly recognizes Hammer & Hand as one of our nation’s select 2015 Housing Innovation Award winning builders paving a path to this home of the future, today.”

The award comes in recognition of our energy consulting on and construction of Pumpkin Ridge Passive House, designed by Scott | Edwards Architecture. SEA and H&H worked together closely to meet our clients’ spatial and aesthetic goals while also achieving the rigorous performance metrics of Passive House.

Pumpkin Ridge Passive House sitePumpkin Ridge Passive House engages a sloping site with sweeping territorial views.

“In an effort to create timeless architecture, all of our designs begin by responding to the site and listening to the owner’s vision. By integrating Hammer & Hand’s Passive House expertise into our design process early, we were able to shape the home into a fusion of performance and design,” said Rick Berry, principal at Scott | Edwards Architecture. “The home’s architecture becomes an expression of its performance imperatives as a low-carbon building.”

Pumpkin Ridge Passive House shading strategiesGenerous roof overhang shades upper floor, while sliding exterior shades manage solar gain on lower floor.

The North Plains, Oregon home, also recipient of the 2014 Best Mainstream Green Home of the Year Award from GreenBuilder Media, has earned three green building certifications: PHIUS+ Passive House, DOE Zero Energy Ready Home, and Earth Advantage Platinum Home. A newly added 9.9 kW solar array will bring the home into “net zero energy” territory, meaning the home should produce as much or more energy than it consumes on an annual basis.

Pumpkin Ridge Passive House Solar PVRooftop solar array at Pumpkin Ridge Passive House.

“It is a tremendous honor to receive this recognition from the U.S. Department of Energy,” said Sam Hagerman, co-owner of Hammer & Hand. “This award confirms what we have discovered in the field – that the same high performance building techniques that revolutionize building energy efficiency also deliver superior indoor air quality, comfort, and building durability.”

The experience of Bryan Farris, owner of Pumpkin Ridge Passive House, bears this out.

“When you put a little more thought and a little more attention into the engineering of the house, you have a house that’s really comfortable, that you really enjoy, that you can stay in for the rest of your life and that you don’t want to leave,” said Bryan. “I don’t know that I can say that for any other houses that I’ve lived in.”

The award will be formally presented to Sam at the EEBA Excellence in Building Science Conference and Expo in Denver this October.

Pumpkin Ridge Passive House wall assembly, cc Hammer & Hand
Components of high performance wall assembly at Pumpkin Ridge Passive House.

Save

The post H&H Wins U.S. Department of Energy’s 2015 Housing Innovation Award appeared first on Hammer & Hand.

]]>
https://hammerandhand.com/blog/hh-wins-u-s-department-of-energys-2015-housing-innovation-award/feed/ 0
HOW MUCH DOES A PASSIVE HOUSE COST? https://hammerandhand.com/blog/how-much-does-a-passive-house-cost/ https://hammerandhand.com/blog/how-much-does-a-passive-house-cost/#respond Fri, 08 Apr 2016 17:46:22 +0000 http://hammerhanddev.wpengine.com/?p=9212 Fair question. But as our colleague Adam Cohen of Passiv Science counters, “how much does a bag of groceries cost?” It really depends. Are you shopping at Whole Foods or at Food4Less? Are you buying canned food and mac-and-cheese or wild salmon and organic veggies? That bag of groceries might cost $15 or $150. The […]

The post HOW MUCH DOES A PASSIVE HOUSE COST? appeared first on Hammer & Hand.

]]>
Fair question.

But as our colleague Adam Cohen of Passiv Science counters, “how much does a bag of groceries cost?” It really depends. Are you shopping at Whole Foods or at Food4Less? Are you buying canned food and mac-and-cheese or wild salmon and organic veggies? That bag of groceries might cost $15 or $150.

The same is true for Passive House projects. Is the project one with lots of high-end finishes? If so, the cost of “adding Passive House” to the project could easily be dwarfed by one’s choices about tile and countertops. Or is the project using budget finishes and Ikea cabinets? Then the Passive House portion of the project will represent a larger percentage of the budget. That said, if client, designer, builder and Passive House consultant work together at project inception to dial-in cost, the extra cost for Passive House can be nominal.

Take the Pumpkin Ridge Passive House, for example. The project team (the client, Hammer & Hand as builder and Passive House consultant, and Scott | Edwards Architecture) set this goal early on: the extra debt service (mortgage payment) for the upfront investment in creating a Passive House was to be offset by the ongoing utility bill savings realized by the superior energy performance of the project as a Passive House. To achieve this goal we worked closely with the client and architect to inform design from the earliest stages of schematic design. We ran hundreds of computer simulations comparing various building form options, shading strategies, glazing schemes, and building assembly approaches to assist the team in finding the most cost-effective Passive House solution that also satisfied the client’s programmatic and aesthetic goals. The result is a design by Scott | Edwards Architecture that expresses the performance imperatives of the house with elegant economy. And by working early in this integrated way with client and architect, we succeeded at delivering a Passive House whose performance pays for itself.

Sometimes, we are brought in later in the project development process, after the client and architect have already made their design decisions about building form and orientation. This is a different “bag of groceries,” albeit one that can be a fun challenge: how to achieve Passive House performance without compromising design decisions already made? When collaboration between client, architect, builder, and Passive House consultant starts late in the design process, we do miss out on many of the more sweeping cost-optimizing opportunities for the project, however.

It’s hard to overstate the importance of process in determining the cost of achieving Passive House performance for a project. If cost is a critical factor in your project (and, ahem, it usually is!) then the best way to save money is to bring client, architect, builder, and Passive House consultant together at the very outset, before schematic design. Passive House design is extremely flexible, and Passive House practitioners have powerful modeling tools at their disposal to help inform the design process and uncover great opportunities for cost savings. But to realize the full value of these tools, this work needs to be done very early in the process, before costly decisions have already been made.

Of course, another big determinant of Passive House project cost is project type. Larger commercial or multifamily projects usually have an advantageous ratio between surface area (the building’s skin of walls, roof, and foundation) and volume (the building’s interior). Because Passive House involves significant investment in creating an advanced building envelope, the smaller the ratio between skin and interior volume the cheaper Passive House becomes to achieve, all things equal. We have colleagues who routinely deliver budget-driven commercial buildings at cost parity with conventional construction.

Depending on what bag of groceries you’re buying, we estimate the cost premium of Passive House at about 10-20% for single family homes and 0-10% for larger commercial projects. We can achieve the low end of those ranges when builder, designer, client, and Passive House consultant are brought together early and often to shape the project.

The post HOW MUCH DOES A PASSIVE HOUSE COST? appeared first on Hammer & Hand.

]]>
https://hammerandhand.com/blog/how-much-does-a-passive-house-cost/feed/ 0
Custom Passive House Door | Woodshop Video Series https://hammerandhand.com/blog/custom-passive-house-door-woodshop-video-series/ Sat, 13 Nov 2021 00:00:43 +0000 https://hammerandhand.com/?p=13271 Every Saturday in October, the Hammer & Hand YouTube posted an episode of our 5-part video series following the construction of a custom passive house door for a home in Idaho. Now that every episode has been posted, you can watch the entire project, from slab of wood to elegant and efficient high performance door. […]

The post Custom Passive House Door | Woodshop Video Series appeared first on Hammer & Hand.

]]>
Every Saturday in October, the Hammer & Hand YouTube posted an episode of our 5-part video series following the construction of a custom passive house door for a home in Idaho. Now that every episode has been posted, you can watch the entire project, from slab of wood to elegant and efficient high performance door. Watch the talented craftspeople in our woodshop skillfully cut and assemble this unique door in our Custom Passive House Door video series on YouTube!

Like, subscribe, and hit that bell to make sure you don’t miss a single episode of our Custom Home Builder videos!

Black Stained Custom Passive House Door by Portland Hammer & Hand Woodshop

Check out our original blog post on this Custom Black Stained Passive House Entry Door.

For more, follow Hammer & Hand on Instagram @hammerandhandbuilds!

 

 

The post Custom Passive House Door | Woodshop Video Series appeared first on Hammer & Hand.

]]>